Modular Design & Rapid Deployment
·Roftop Integration: The cooling station is mounted on roof frame beams, with cooling towers positioned above, optimizing space utilization while avoiding ground-level congestion.
·Plug-and-Play Modules: Factory-preassembled components (chiller sources, hydraulic/pipeline modules, water treatment systems) enabled on-site assembly within a short time—aligning with the project's record-breaking 'Gangcheng Speed'.
Engineering Breakthroughs
·Zero-Leak Waterproofing: Full-seam welding + institutionalized water-diversion design eliminated leakage risks at module joints, critical for rooftop operation in humid climates.
·Precision Manufacturing: All piping pre-tested for dimensional accuracy in factories, reducing field error rates versus traditional welding.
·Cooling Tower Optimization: Simplified lift-and-connect installation slashed deployment time.
·Air-Liquid Compatibility: This project features a dual-mode compatible design where air-cooling and liquid-cooling systems share a unified cooling source. The integrated system utilizes heat exchangers and modular distribution piping, supporting both cooling modes with flexible configuration. During operation, the cooling method can be dynamically selected based on real-time load requirements to ensure optimal energy efficiency.
Synergy with Green Data Center Goals
Accessen's solution directly supports the park's industry-leading sustainability targets:
1. Liquid Cooling Compatibility: 85% liquid-cooled server racks—the highest ratio in China’s data centers—rely on stable, high-efficiency chilled water supply.
2. Ultra-Low PUE: The prefab station’s optimized thermal transfer complements the park’s average PUE of <1.25, far below the 1.55 industry baseline.
3. Renewable Integration: Designed for future coupling with the park’s 80% green energy supply (targeting 100% by 2030).
Why This Matters for Future Data Centers
·Scalability: Modular design allows capacity expansion without service interruption—critical for phased deployments.
·Carbon Accountability: Cuts embodied carbon by minimizing on-site construction and rework, supporting the park’s zero-carbon roadmap.
·Industry Benchmark: Sets a precedent for China’s “Eastern Data, Western Computing” strategy, where rapid, green deployment is non-negotiable.
'Prefabrication isn't just faster—it's the only way to achieve precision engineering for tomorrow's 100% renewable-powered data centers.'
— Accessen Engineering Team
Project Name: Gangcheng Intelligent Manufacturing Data Park
Location: Leyu Town, Zhangjiagang
This 90-billion-yuan mega-project is a cornerstone of China’s digital infrastructure strategy, designed to deliver 165 MW IT capacity and support 23,000P FLOPS of computing demand upon full operation. As the future AI computing hub for ByteDance in East China, it requires mission-critical thermal management to handle real-time computational loads.